MTI Standards &Quality Policy
The following figure illustrates which standards &quality policy MTI uses on its control cabinets. Please click on a label to receive additional information.
a - Frequency Converter
Electronic control unit for controlling mixing drives used by MTI.The frequency converters specially designed for the given requirements have extensive power reserves that guarantee a stable speed with optimized torque on the mixing tool.
Manufacturer - EmotronIncreased peak torque up to 320% of the rated load torque of the motors used by MTI.
Technical implementation in accordance with:
EN 60204-1
b - Safety Load Break Switch
Technically mature systems require a high technical safety standard.In accordance with the standard, MTI uses reliable 3-pole load break switches with fuse line as system, cable and circuit breaking for the main heating and cooling mixer drives.
Technical implementation in accordance with:
EN 60204-1
c - Power Contractor
Depending on the status of the respective drives used that are designed for use under difficult conditions, the associated power contractors are generously dimensioned for our heating and cooling mixers.Technical implementation in accordance with:
EN 60204-1
d - Tab Fuses
Fusing as system protection and circuit breaking.Implementation according to need.
Technical implementation in accordance with:
EN 60204-1
e - Automatic Circuit Breakers
Internal control voltage and circuits are selected by us via automatic circuit breakers and fused.MTI always pays attention to the technical safety defaults for fusing downstream components and systems within the invidual electric and stress circuit.
Technical implementation in accordance with:
EN 60204-1
f - Power Supply
MTI uses power supplies from experienced manufactures in order to maintain contant control voltages, in this case control voltage 24V DC potential-free, short circuit and no-load proof.Technical implementation in accordance with:
EN 60204-1
g - Load Break Switch
Separation from the main power netework is achieved by a load break switch functioning as a mains voltage isolator.It is operated by an ergonomically arranged handle in the switching door.
Control cabinet power supply
40 kW-750 kW
Technical implementation in accordance with:
EN 60204-1
h - PLC (automation system)
Reached by a programmable control unit (PLC), if needed.The connection between the automation system and the system components is achieved on the Profibus level.
Depending on equipment status, continued operation of the mixer systems can be converted to a graphical control terminal, e.g. an OP 170 B Siemens make.
Automation system type:
Simatic S7-300
CPU313C or CPU313C-2 DP
Technical implementation in accordance with:
EN 60204-1
i - Safety Relays and Switching Devices
For monitoring independent safety circuits, e.g. standstill monitoring of mixing tools, etc.Technical implementation in accordance with:
EN 60204-1
j - Control / Safety Relays and Switching Devices
Monitoring of emergency stop safety circuits (call from emergency stop button) and the mixer locking mechanism.Technical implementation in accordance with:
EN 60204-1
k - Coupling Relays / Potential-free Contacts
Separation between different voltage potentials internally / externally.Technical implementation in accordance with:
EN 60204-1
l - Measuring Transducer
Analog (normalized) input and output signals are processed for transmission and further use in the automation system (PLC).Technical implementation in accordance with:
EN 60204-1
m - Plug-in Connectors
Plug-in connector lines to connect the MTI control cabinet to the circuit / terminal boxes of the mixing systemTechnical implementation in accordance with:
EN 60204-1
n - Terminal Strips
Area for connecting optional peripheral and field devices, e.g. signal elements in accustical and/or optical implementation.Technical implementation in accordance with:
EN 60204-1
o - Equipotential Bonding
Elektrische Störgrößen, zum Beispiel Überspannungen oder gefährdende Körperspannungen, stellen nach wie vor ein Gefahrenpotential für Mensch und Maschine dar.MTI begegnet diesen Gefahren, indem an die Systemen zahlreiche Potential-Verbindungspunkte zum Anschluss an die bauseitige Potential-Ausgleichserde platziert werden.
Technische Ausführung gemäß:
EN 60204-1